8
Specifications
Electrical: Voltage Input: 16.5 VAC 40 VA from supplied transformer
External Speaker: 10 Watt minimum, 8W horn type - Ademco 713 or equivalent. Total
speaker load must be between 4W and 16W.
Internal Speaker: Speaker supplied in all compatible keypads. For stand-alone operation
10 Watt minimum, 8W - Ademco 746 or equivalent. Total speaker load must be
between 4W and 16W. For UL installations, an Ademco 705 speaker must be connected to
the "EXT" and "COM" terminals.
Auxiliary Power Output: 13.5VDC, 1.85 AMP max - Not evaluated for UL installation
Switched Fire Output: 13.5 VDC, 1.85 AMP max
Two Wire Smoke Detectors: Up to 12 per system
Note: Switched Fire Output and Two Wire Smoke Detectors are not to exceed
10mA in a UL installation
Back-up Battery: 12VDC, 7AH gel cell. YUASA NP7-12 or equivalent.
For UL installations use 2 - batteries with SA5140-1 cable assembly
CAUTION: Total current draw of Auxiliary + Smoke + 4 wire bus power is not to exceed 2
Amps. In UL installations total current draw must not exceed 400mA. Test installation for 1
minute in alarm to ensure sufficient power.
Communicator: Supports: 3/1, 4/1/1, 4/2 extended, Ademco Contact ID
49 report codes
DTMF and pulse dialing
DPDT line seizure
Two telephone numbers and two account codes, dial both numbers
Split reporting of selected codes
Alternate number dialing if primary number fails
Programmable number of dialing attempts
Programmable to enable or disable the communicator
Two-Way Voice: Microphone inputs: 3 separate, individually controlled channels.
Microphone: 5V shielded 2 conductor omnidirectional electret condenser microphone.
Frequency response 50-10K. -64db sensitivity, TWM-25K or equivalent.
System Zones: 96 using the following inputs:
80 - programmable fully supervised wireless alarm points (with H series receiver)
16 - programmable fully supervised hardwire inputs on the control panel
64 - programmable fully supervised hardwire inputs on multiplexed expansion boards
1 - 2-wire smoke loop
8 - keypad alert
8 - wireless keypads (when available)
1 - local phone activation
1 - remote phone / phone line monitor activation
8 - X-10 sending units (Not UL listed for fire or burglary functions and are intended for
home automation.)
Auxiliary Outputs: 1 - Form C 10A 24VDC system relay
7 - Pull to ground, 12 volt, 100mA outputs, not to exceed 500mA total.
Not to be used in a UL installation