System Option Automated Programming Locations
Clear event memory log and long term memory
...............................................................
9898
Enter Phone # for automatic download (From system Keypad only)
..................................
9904
Enter Account # for automatic download (From system Keypad only)
...............................
9909
Speak automatic download Phone #
..................................................................................
9914
Speak automatic download account #
...............................................................................
9919
Initiate direct connect computer programming
.................................................................
9952
Initiate unattended programming download (Not permitted for UL installation)
...............
9953
Initiate unattended event memory log upload (Not permitted for UL installation)
............
9954
Speak software revision number
........................................................................................
9990
Set time/date (HH - Hr., MM - Min., W- Day of the week, MM- Mo., DD- Day, YY- Yr.) 9991
Set automatic arm/disarm times (24 Hr format - Not permitted in a UL installation)
........
9993
Speak time and date
..........................................................................................................
9996
Set automatic Event Memory Log upload time
.................................................................
9997
System Options - Group 1
Options - Enter Total Location Value
Automatic time control of remote channels in AWAY mode only
......................................
002
Disarm before rearm
..........................................................................................................
004
Mute external Speaker (external driver -off, internal driver - adjustable)
...........................................
008
Access code before arm
....................................................................................................
016
Speak pre-alarm instead of tone
........................................................................................
032
3 digit disarm code
............................................................................................................
064
Speak system status with 1st digit of a user code
..............................................................
128
Default
..................................................................................................
0130
...................
164
System Options - Group 2
Options - Enter Total Location Value
Automatic "force arm" (no second key press) (Not evaluated for UL installation)
............
004
No exterior instant exit delay
............................................................................................
008
No entry delay for Exterior Delay 1 in HOME mode
.........................................................
016
Auto 96 hr clear of long term memory and event memory log
..........................................
032
Zone trouble = zone activation when armed
.....................................................................
064
Default
..................................................................................................
0131
...................
000
System Options - Group 3
Options - Enter Total Location Value
Speak time remaining and end of exit delay (inside speaker every 10 seconds)
...............
001
Track activations and record in Long Term Memory
..........................................................
002
Voice driver
.......................................................................................................................
004
*
{ Enable split arming (Not permitted in a UL installation) .................................................. 008
Echo local phone speech to inside speaker
.......................................................................
016
Enable night mode
.............................................................................................................
032
Enable two-way voice call back (Not evaluated for UL installation)
................................
064
Default
..................................................................................................
0132
...................
039
* Note: When using Split Arming, all zones MUST be assigned to an area (zone option 2). Any zones
without an area assignment WILL NOT CAUSE AN ACTIVATION WHEN ARMED! It is
strongly recommended to use PC software on all systems that utilize Split Arming.
Split Arming requires all RKLCD keypads to run software 4.03 or later.