20
System Input Overview
The diagram below shows each of the available system input types and the maximum number of each device that
can be integrated into the system.
Programming System Inputs
Before programming, determine all of the system inputs that are being used and assign a zone number for each
input. All zones may have one input and each input can only be assigned to one zone. Each loop on a multiple
input transmitter is considered to be a single input. Therefore, if all three inputs on a three loop transmitter are
being used, each input is assigned to a different zone.
8
X-10 Sending
Units
1
Two Wire Smoke Loop
8
Keypad Alarm Points
1
Phone Alarm
80 Wireless Alarm
Points / Portable inputs
(with H series receiver)
8
Wireless Keypads
(When available)
16
Hardwire System
Inputs
64
Expansion Hardwire
Inputs
Each input used is assigned to a System Zone.
There are 96 System zones available.