44
Duration between The length of time the system pauses before saying "Entry Detected." The shortest time
pre-alarm cycles: period is three seconds (000). Any value in this location is added to the default 3
seconds.
Burg tone before speech: The length of time the system will create a burglary tone before speech.
Fire cut off and reset: The length of time the system will stay in alarm without a disarm before the system
stops the sirens and waits for another zone activation. Fire cut off and reset is not
permitted in a UL installation.
Phone samples: The built in phone monitor circuit can be adjusted based on the installation location.
Every four seconds, the phone line is sampled, this option determines the number of
samples needed for the panel to determine that a valid phone line has been connected
or removed. In locations subject to brief phone outages use a higher number, in
locations that have reliable phone service use a lower number. The default 6 works
best in most applications.
User Test Timeout: Controls the amount of time before the User Test Mode will automatically time out.
Answer service time: This option is active only when Answer Service Override is enabled. This value
determines the amount of time the panel will wait for a second call after hearing two
rings on the first call.
Automatic Arming and Disarming
Arm State: To automatically arm the system, include AWAY or HOME in the total for the
"Automatic Arm / Disarm" option.
Disarm: To automatically disarm the system, include Disarm in the total for the
"Automatic Arm / Disarm" option.
Force arm w/ open zones: To automatically force arm around open zones, include force arm around open zones in
the total for the "Automatic Arm / Disarm" option. If this option is not used the panel
will not automatically if a zone is open.
5 day cycle: The automatic arm/disarm feature will occur every day unless the 5 day cycle is
included in the "Automatic Arm / Disarm" option. The 5 day cycle is Monday through
Friday.
Monitor Trouble Conditions
Monitor trouble: The system can speak and indicate a high current situation, control low battery, and a
failure to complete a digital communication as trouble conditions at the keypad.
Entering 001 will enable speech and show the condition at the keypad while 000
disables this feature. This feature must be enabled in a UL installation.
Battery trouble: Enables Battery test every 3 minutes. If the backup battery is under 10 volts, low
battery can be displayed at the keypad and / or sent to the central station. This option
must be enabled in a UL installation.