Enter Remote Control: The 56 remote control channels can be accessed by telephone, keypad or wireless
keypad. Enter remote control by entering 8,8,8,8 from any keypad or phone, or by
pressing 1 & 7 (or programmed function key) simultaneously on a keypad, the system
will enunciate a list of remote control channels available in the system. Enter two
digits from 01 to 56 that represent the device to be controlled. The system will echo the
word description. The A key turns the unit on and the H key turns the unit off. If the
dimming option is not programmed, pressing the A key will toggle on and off. If the
dimming option is selected, the first press of A will turn the unit on and subsequent
presses of A will take the unit (only for X-10 not auxiliary output) through six stages of
dimming. Each stage is echoed in speech by number from 1 to 6. After 6, the unit turns
off. If a key is not pressed within 20 seconds, the control will automatically exit remote
control. To manually exit remote control, enter 00 as the unit number.
Extended Monitor A/B: With the system disarmed, entering a full function user code followed by the 3 or 4
digit, will place the system into extended monitor mode A or B. The system will speak
"MONITOR ON" through the inside speaker. Entering a full function user code followed
by 3 or 4 will clear any active extended monitor zones and stop the extended monitor
beep or speech. The system will speak "MONITOR RESTORED." If the system is in
extended monitor mode and there are no extended monitor zones active, entering a full
function user code followed by 3 or 4 will take the system out of extended monitor
mode. The system will speak "MONITOR OFF".
The enunciation feature of the control panel can be used to monitor exterior, interior,
and follower zones. As an example, it may be desirable to monitor interior door
activity of residents in a retirement home. Normal extended monitor activity is not sent
to the central station. If a Day Zone causes an Extended Monitor activation when the
system is not armed, a Day Zone Trouble can be sent to the central station.
There are two different levels or types of extended monitor, A and B. Locations 0238
and 0239 determine which zone types are to be monitored by each extended monitor
type. Entering a full function user code followed by the digit 3 will place the system in
extended monitor mode type A or enter the 4 digit for extended monitor type B. When
entering extended monitor the system responds with "MONITOR ON" through the inside
speaker.
NOTE: You can only enter the extended monitor mode when the system is disarmed. If
the system is in extended monitor mode it will automatically exit that mode when the
system is armed.
Enter Time: The panel will prompt for a 4 digit time (use a leading 0 for times under 10:00),
followed by a prompt for AM or PM. The next prompt is for the day of the week (1-
Sunday, 2-Monday, 3-Tuesday, 4-Wednesday, 5-Thursday, 6-Friday, 7-Saturday).
Enter a two digit month, two digit date and two digit year.
Step Arming: Each time a step arming button is depressed, the system steps the arming stage in order
between the following stages. Starting with the system disarmed, the first press will arm
the system to AWAY. A second press, before exit delay time expires, will arm the
system to HOME. A third press, or a second press after exit time has expired, will
disarm the system. Arming to Night is not available with step arming. If split arming is
enabled, user code 32 will determine which areas are armed or disarmed. Even if force
arming is not programmed, the system will always force arm any open zones when step
arming is used. The step arming button function reports to the central station as user
code 32. Step arming is not evaluated for UL installation.
Arm to AWAY: Arm the system to AWAY, all open zones are force armed.