Using This Manual:
This manual is not designed to be read like a book. The layout is intentionally designed as a reference guide that
allows quick access to information while programming the system. It is strongly recommended that a first time
installer attended training or bench test a system before attempting the first installation. For information on APEX
training contact the sales department at 800-272-7937.
The layout of this manual is broken into eight separate sections. Each section begins with locations and ends with
a full description of each option found in the location section. There are four styles of programming information in
the system:
Automated Locations: Automated Location prompt for specific information and automatically record the
appropriate information into the correct locations.
Value Locations: A documented location that contains a specific value (i.e. time, user number, etc.)
Option Location: Most system options require a total of option values to be placed in a location.
Example:
Options - Enter Total Location Value
Speak remote control menu (Not evaluated for UL installation)
................................
001
Speak time and date when time is requested
..............................................................
002
Speak temperature when time is requested (See "Using a TS16")
................................
004
Enable answer service override callback
.....................................................................
008
Default
..............................................................................................
0135
................
003
The bold 001 and 002 states the values are included in a defaulted panel. To include the 3rd option,
add 004 and enter the total (007) in location 0135. If no options were selected, enter 000.
Charts: Charts are used to provide a large number of locations in a small space. Depending
on how the section is used, the locations in charts contain either an option value or
a discreet value.
Example:
Options Value
2 end-of-line resistor supervision
..................................................................................
064
No end of line resistor (Not evaluated for UL installation)
..........................................
128
Default (1 end-of-line resistor)
.....................................................................................
000
The inputs across the top refer to which of the 16 terminals across the top the location is referring to.
Below each input is a location. To program system input number 11 for 2 resistor supervision, enter
2474,064. Each location referenced above is shipped with a 000 default.