Zone Options 2
Area: When Split Arming is enabled, this option determines which of the 8 areas the zone is
assigned. Do not add multiple areas.
Suppress monitor: This option will prevent a zone from being enunciated when the system is in monitor
mode.
Suppress open: This option will prevent the system from speaking the word "OPEN" at the end of a zone
description. This is useful when the object being monitored does not have an open or
closed state such as a driveway motion detector.
Suppress siren: This option will cause a zone that normally produces an audible activation to produce a
silent alarm. The activation appears in system status and on an LCD display, however
no audible indication is given.
System and HWB416 Inputs
Two resistor supervision: When an input is programmed to be completely supervised, the control will recognize
traditional opens and closes as well as a break or short in the loop. A break or short
can produce a zone trouble condition which will be shown on the keypad. If
programmed, trouble condition can cause an alarm condition if the trouble occurs while
the system is armed. A trouble will clear when the loop has been corrected. See
"Hardware and Wiring" for a wire loop diagram. Fire zones are fully supervised with
one resistor and can not be wired with a 2 resistor combination.
No end-of-line resistor: With this option selected, the panel does not look for a 4.7KW resistor on the input loop.
This option can only be used with normally closed loops. No End-of Line Resistor is not
evaluated for UL installation.
Using a TS16 - Only use between 32 - 127 degrees F
Enable TS16: If a TS16 is installed, use this option to enable the TS16 options. TS16 sensors not
evaluated for UL installation.
Speak transmissions: A TS16 sends a temperature each time the temperature changes. In addition, a TS16
sends a status message every minute or ten minutes based on the dip switch setting.
With this option set, the panel will speak the temperature each time a message is
received from the TS16.
Temperature with time: With this option set the selected TS16's description and temperature will be spoken
whenever time is requested. Note: option 004 in System Options - Group 6 must be set
for this option to function.
Use High/Low Setting: This option determines if the High and/or Low trip points should be used to cause a zone
activation. If neither option is selected, the zone will never show open.
Hysteresis: This setting specifies how much the temperature must fall below the high setpoint or rise
above the low setpoint for a close to occur. Hysterics settings of 2 and 4 can be added
(192) for a hysterics of 6 degrees. If values 64 and 128 are not used, the hysterics is 1
degree.
High/Low setting: These temperature settings determine when the panel will show the attached zone as
open or closed. The zone will show open when the setpoint is reached. To prevent
open/close cycling when the temperature is around the setpoint, a hysterics option is
available.
Note: If a Low setpoint and High setpoint are being used then:
Low + hysterics must be less then High - hysterics. See "Key Function Values" in the
Keypad Functions section for definition of terms.