System Terminals
House Phones: The R1 and T1 terminals provide telephone service to the house if the installation
contains an RJ-31X terminal block for true phone line seizure.
Telephone Company: The incoming telephone service is wired through an RJ-31X jack to the R and T
terminals on the control panel. If regular phone service is unavailable, the system will
provide power and a distinct system tone to all in house phones.
Speakers: The control panel contains amplified internal and external siren drivers. Both internal
and external speaker connections require 8W , 10 watt (minimum) speakers. The "EXT"
and "COM" (speaker common) terminals provide full volume audio during activation.
Mount the external speaker(s) in an area that is unaccessible to intruders and will
provide a sufficient volume during an activation.
The INT and COM terminals produce speech, low volume monitor beeps, keypad
echo beeps, system status, pre-alarm warning, and a high volume alert during
activation. Typically, in non UL installations, the speakers (16W) in the RK series
keypads are used as the only source for providing internal system audio; however in a
UL installation the RK series keypads must be supplemented with an Ademco 705
speaker connected to the "EXT" and "COM" terminals. See Specifications for
compatible speakers.
Wire all speakers in a series/parallel combination that does not allow the impedance for
either the internal or external output to drop below 4W.
Transformer (AC Power): Use a 16.5 VAC, 40 VA transformer (supplied) to supply AC power. Do not connect the
transformer to a switched AC outlet. If an AC failure occurs, after 1 minute
(programmable) the system will speak "POWER OFF", the keypad power LED will turn
off, and the keypad status LED will begin to flash. After requesting system status the
system will speak "POWER OFF" and the status LED will become solid. AC failure and
restore conditions can be transmitted to the central station.
2-Wire Smoke Detectors: 2-wire smoke detectors are connected to the "SMK+" and "SMK-" terminals. Be certain
to observe polarity. Smoke power reset is built into the panel by entering a valid full
function user code followed by the "6" digit. A 4.7KW resistor must be wired in parallel
with the last detector in the loop. If a resistor is not used, or if there is a break in the
loop, a TROUBLE indication will occur. Up to 12 2-wire smoke detectors can be
powered by the smoke power supply. A high current situation on the smoke power
circuit can be indicated at the keypad and/or communicated to the central station.
4-Wire Smoke Detectors: The "SMK+" terminal supplies up to 1.85 AMPs of power. A 4.7KW resistor must be
wired in parallel with the detector and wired to a zone input. Power is drawn from the
SMK+ and COM terminals. Smoke power reset is built into the panel and is reset by
entering a valid full function user code followed by the 6 digit. A high current situation
on the smoke power circuit can be indicated at the keypad and/or communicated to the
central station. Use of 4-wire Smoke Detectors not evaluated for UL installation.
Auxiliary Power: 12V+ Auxiliary power for hardwire devices such as motion detectors and glass break
detectors is available on the "AUX" terminal. The auxiliary output is protected at 1.85
Amps. A high current situation can be indicated at the keypad and/or communicated to
the central station.
The Destiny-6100 is compatible with the ADEMCO 4142-BLK removable terminal strips. If
necessary, these connectors allow for quick replacement of the control board.