39
Phone Access Options
Options Time Increment Location Default
Number of rings for pickup (minimum of 002, 000 disables )
............................................
0458
.......
010
Inactivity time before automatic hang up while in user phone access
..
seconds
..............
0780
.......
015
Inactivity time before automatic hang up/exit when programming
.......
seconds
..............
0781
.......
060
Event Memory Log
Choose upload days total Location Value
Sunday
...............................................................................................................................
001
Monday
.............................................................................................................................
002
Tuesday
.............................................................................................................................
004
Wednesday
........................................................................................................................
008
Thursday
............................................................................................................................
016
Friday
................................................................................................................................
032
Saturday
............................................................................................................................
064
Clear Event Memory Log after upload
...............................................................................
128
Default (Report on the 1st of every month)
...........................................
0245
...................
000
Number of retires when dialing
............................................................
0246
...................
008
System Options and Times Terms
System Option Automated Programming Locations
Clear EML and LTM: The Event Memory Log and Long Term memory can be cleared by entering 9898.
Unattended program Used in installations where the programming for the panel is entered into the PC
download: software prior to the installation of the control panel. The software is left in auto answer
mode allowing the panel to call to PC, match numeric account numbers, and download
the programming file. Use location 9909 to set the panel account number and enter the
PC phone number in 9904 (shared with automatic EML upload). To initiate to automatic
download sequence enter 9953. (Unattended Program Download not permitted for UL
installation.)
Direct connect: Used with the PC software. Connect the modem to any in-house phone jack or to the
panel's R and T terminals. Activate the direct connect option in the PC software and
with the control panel in program mode, enter 9952.
Event Memory Log: The control panel has a built-in 512 event system memory log (EML) that can be
retrieved manually with the upload/download software package or automatically by
programming the control panel to call a computer with the upload/download software
running in the automatic EML upload mode.
Automatic EML upload: The event memory log can be automatically uploaded to a PC in auto answer mode.
Program location 0245 to select the day or days of the week to upload the event
memory log. To upload on multiple days, the values can be added. Choose a time to
upload the log and enter the time in 24 hour format in location 9997. Use location
9909 to set the panel account number and enter the PC phone number in 9904 (shared
with unattended program download).
Speak software revision: As dealers present ideas for new control panel options, the software is updated, although
all software is labeled, this location verifies the software revision number.