71
System Triggers
This feature is not UL listed for fire or burglary functions and is intended for home automation
Event Location Channel Location Option
Any alarm activation
.........................................................
0183
...........
000
.................
4053
............
006
Burglary
.............................................................................
0184
...........
000
.................
4054
............
006
Fire
....................................................................................
0185
...........
000
.................
4055
............
006
Panic
.................................................................................
0186
...........
000
.................
4056
............
006
Silent Panic
.......................................................................
0187
...........
000
.................
4057
............
006
Pre-alarm
...........................................................................
0189
...........
000
.................
4059
............
006
Extended Monitor
..............................................................
0190
...........
000
.................
4060
............
006
Remote Phone Access
.......................................................
0191
...........
000
.................
4061
............
006
Emergency
.........................................................................
0192
...........
000
.................
4062
............
006
*
{
Arm to HOME ...................................................................
0193
...........
000
.................
4063
............
006
Arm to AWAY ....................................................................
0194
...........
000
.................
4064
............
006
Arm to NIGHT ...................................................................
0209
...........
000
.................
4079
............
006
Arm to HOME, NIGHT, or AWAY
......................................
0195
...........
000
.................
4065
............
006
Disarm
...............................................................................
0196
...........
000
.................
4066
............
006
Access code entered
..........................................................
0197
...........
000
.................
4067
............
006
Alert
..................................................................................
0198
...........
000
.................
4068
............
006
Loss of phone line
..............................................................
0199
...........
000
.................
4069
............
006
Duress Disarm
...................................................................
0200
...........
000
.................
4070
............
006
Duress when not armed
.....................................................
0201
...........
000
.................
4071
............
006
AC Fail
..............................................................................
0202
...........
000
.................
4072
............
006
Two-way Voice
..................................................................
0203
...........
000
.................
4073
............
006
Smoke reset
.......................................................................
0204
...........
000
.................
4074
............
006
Speech Activation
.............................................................
0205
...........
000
.................
4075
............
006
Ring Detect
.......................................................................
0206
...........
000
.................
4076
............
006
House Phone Off Hook
......................................................
0207
...........
000
.................
4077
............
006
Communicator Fail
............................................................
0208
...........
000
.................
4078
............
006
*Note: Arming and Disarm trigger outputs are disabled when Split Arming is enabled
Option - Enter Total Value
Activation Action
Turn Control Channel Off
..............................................................................................
001
Turn Control Channel On
...............................................................................................
002
Restore Action
Turn Control Channel Off
..............................................................................................
004
Turn Control Channel On
...............................................................................................
008
Default
..........................................................................................................................
006
X-10 Options
This feature is not UL listed for fire or burglary functions and is intended for home automation
Options Location Default
Number of times an X-10 transmission is made
.............................................................
0793
............
001
Delay before an X-10 transmission is made
...................................................................
0794
............
001
Option - Enter Total Location Value
Enable Echo mode - speak all incoming X-10 Channel / Unit Assignments
...................
001
Include panel transmission in Echo mode
......................................................................
002
50 Hz X-10 mode
..........................................................................................................
004
X-10 Options
...........................................................................................
0788
............
000