AMX APEX Destiny 6100 Especificaciones Pagina 64

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 63
64
Speak Alert Memory: To hear all activations stored in LTM enter a full function code followed by the 8 key.
The LTM will be spoken in order starting from the most recent activation. If there are
no activations stored, the system will sound three beeps. LTM and EML can be
simultaneously cleared by entering 9898 in program mode. LTM will store 8
activations. If there are more than 8 activations, the oldest will drop off leaving room
for the most recent.
Bypass Mode: To bypass individual zones, enter a valid full function code followed by the 9 digit. The
system will speak "BYPASSED MODE, ENTER ZONE NUMBER." Press a two-digit zone
number (leading zero if necessary). The current bypass state of the zone is spoken.
Pressing A toggles the bypass status (confirmed in speech). Pressing H exits bypass
mode. To unbypass all bypassed zones, enter 00 as the two-digit zone number.
The following are system operation notes relative to bypass:
1) Bypassed zones will display open/close if programmed to do so.
2) Bypassed zones that show as open are ignored for purposes of forced arming.
3) No monitor speech or beep or alarm activation will occur for a bypassed zone.
4) Only zones that exist in the system can be bypassed. The system will issue 3-beeps
if an invalid zone number is entered.
5) If the system is programmed for split arming, only zones in the partition(s)
controlled
by the user code you use to enter bypass mode can be bypassed.
6) Fire zones and disabled zones cannot be bypassed.
7) As a programmable option, any bypassed zone will automatically unbypass the next
time the system is disarmed. If this option is not programmed, bypassed zones will
remain bypassed until they are manually unbypassed.
Bypassing is not permitted in a UL installation.
User Test Mode: See "Central Station Features."
Extended Monitor
Extended Monitor This option determines the amount of time an extended monitor activation will remain
in
keypad display time: system status.
Time between beeps: When using the extended monitor mode as an enunciator, you may wish to have
audible indication as well as visual. The extended monitor speech or beep will sound at
intervals determined by this time. Valid times are from 1 to 255 seconds. If a value of
000 is programmed, NO speech or beep will be heard.
Zone type assignment: The extended monitor function is based on zone types, input the total of all of the zone
type values that are to be monitored by the extended monitor function.