Set time and date: After entering 9991 the system will prompt "Enter Eleven." The time, day, and date are
entered in the following format HHMMWMMDDYY.
HHMM - Military time, if the hour value is less than 10 use a leading zero.
W - Day of the week: 1-Sun 2-Mon 3-Tue 4-Wed 5-Thr 6-Fri 7-Sat.
MM - Month. Months less than 10 use a leading zero.
DD - Day of Month. Days less than 10 use a leading zero.
YY - Enter the last 2 digits of the year.
Auto arm/disarm: Choose the arming and disarming options and enter the total in location 0169. Use
location 9993 to enter the arm and disarm times in 24 hour format. Location 0169
requires the sum of selected options. If 001 and 002 are programmed together, arming to
AWAY will take precedence. If arm and disarm options are both selected, setting the
same time for both will never produce an automatic disarm. When 016 is not selected
and there are zones open the system will not arm. In a partitioned system, the control
will use the areas designated for user code 32 to determine areas to arm and/or disarm.
Automatic arm/disarm is not permitted in a UL installation.
Speak time and date: This allows a convenient method to check the system time and date in program mode.
System Options - Group 1
Control of remote With this option programmed, the automatic turning on and off of control channels will
channels only in AWAY: take place when the system is armed to AWAY. Control channels are not UL listed for
fire or burglary functions and are intended for home automation.
Disarm before rearm: With this option selected, the system can only be armed from AWAY to HOME after
disarming and vice versa. This prevents an intruder from turning off interior protection if
they are able to circumvent perimeter protection.
Mute external speakers: This option sends all tones to the inside speaker and is adjustable with the inside speaker
volume adjustment. The external speaker channel is turned off. The main use of this
feature is for testing alarm activations.
Access code before arm: In this configuration, a full access code (arm/disarm code) must be entered to arm the
system. Once armed, the system must be disarmed to allow a change from one arming
mode to another.
Speak pre-alarm: When this option is selected the system will repeat "ENTRY DETECTED" followed by a
zone description during pre-alarm in place of a low volume siren tone.
3 Digit disarm code: This is a global option that converts all access codes to 3 digits instead of the traditional
4 digits.
Speak system status: When this option is selected, the system speaks status through the inside speaker or over
the phone three seconds after pressing the first digit of a disarm code.
System Options - Group 2
Automatic force arm: Without this option enabled, if a user attempts to arm the system with a zone open, the
system will respond with "ZONES OPEN". The user can then "force arm" around the
open zone. This temporarily bypasses the zone until the zone is closed. If this option is
enabled, the open zone will automatically be temporarily bypassed (force armed) on the
first key press. The user is never notified that zones are open unless system status is
requested. Automatic force arm is not permitted in a UL installation.
No exterior instant When enabled, this option will eliminate the exit delay on all exterior instant zones
exit delay: following arming to either HOME or AWAY.