AMX NXV-300 Especificaciones Pagina 54

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 53
NetLinx Programming
"^" Button Commands (Cont.)
^TEF Set the text effect. The Text Effect is specified by name and can be found in TPD4.
Syntax:
"'^TEF-<vt addr range>,<button states range>,<text effect name>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
text effect name = Refer to theText Effects table on page 49 for a listing of text effect names.
Example:
SEND_COMMAND Panel,"'^TEF-500.504&510.515,1&2,Soft Drop Shadow 3'"
Sets the text effect to Soft Drop Shadow 3 for the button with variable text range 500-504 and 510-
515.
^TOP Enables/disables touch output to Master. If enabled, Press/Move/Release events are sent to the
Master as string events.
Syntax:
"'^TOP-<state>'"
<state> is 0(disable) 1(presses/releases), 2(moves), 3(press/move/release).
Note: Move should be used with caution. This setting can generate a significant amount of traffic to
the master depending on user interaction.
Example command: "'^TOP-1'"
Example Response: "String Event: Text: Press,320,480"
Example Response: "String Event: Text: Release,320,480"
^TXT Sets Non-Unicode text. Assign a text string to those buttons with a defined address range.
Syntax:
"'^TXT-<vt addr range>,<button states range>,<new text>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
new text = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^TXT-500.504&510.515,1&2,Test Only'"
Sets the On and Off state text for buttons with the variable text ranges of 500-504 &
510-515.
^UNI Set Unicode text. For the ^UNI command (%UN and ^BMF command), the Unicode text is sent as
ASCII-HEX nibbles.
Syntax:
"'^UNI-<vt addr range>,<button states range>,<unicode text>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
unicode text = Unicode HEX value.
Example:
SEND_COMMAND Panel,"'^UNI-500,1,0041'"
Sets the button’s unicode character to ’A’.
Note: To send the variable text ’A’ in unicode to all states of the variable text
button 1, (for which the character code is 0041 Hex), send the following command:
SEND_COMMAND TP,"'^UNI-1,0,0041'"
Note: Unicode is always represented in a HEX value. TPD4 generates (through the Text Enter Box
dialog) unicode HEX values. Refer to the TPDesign4 Instruction Manual for more information.
Vista de pagina 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 79 80

Comentarios a estos manuales

Sin comentarios