AMX NI-3100 Especificaciones Pagina 50

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 160
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 49
WebConsole - System Options
40
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
Using Multiple NetLinx Masters
When using more than one Master, each unit must be assigned to a separate System value.
A Master’s System value can be changed but it’s device Address must always be set to zero (00000). The
Device Addressing dialog will not allow you to alter the NetLinx Master address value.
Example: Using an NI-2000 and NI-4100:
The NI-2000 could be assigned to System 1 (with an Address of 00000).
The NI-4100 could be assigned to System 2 (with an Address of 00000).
Resetting the Master Controller to the Factory Defaults Configuration
Click the Reset To Factory Defaults button. This resets the Master to its’ factory default state. This includes:
Removal of all security settings
Removal of all user files
Resetting to DHCP
Loading an empty NetLinx program.
Once reset, the Master will be effectively in an out-of-box state.
It may be necessary to refresh the browser window after the master has finished
booting (click Refresh).
Vista de pagina 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 159 160

Comentarios a estos manuales

Sin comentarios