Initial Configuration and Firmware Upgrade
5
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
Initial Configuration and Firmware Upgrade
Overview
This section describes using the NetLinx Studio software application to perform the initial configuration of the
Master, as well as upgrading the firmware for various Master components.
NetLinx Studio is used to setup a System number, obtain/assign the IP/URL for the connected NI
Controller, and transfer firmware Kit files to the Master.
NetLinx Studio is available to download (free of charge) from www.amx.com.
Before You Start
1. Verify you have the latest version of NetLinx Studio on your PC. Use the Web Update option in NetLinx
Studio’s Help menu to obtain the latest version. Alternatively, go to www.amx.com and login as a Dealer
to download the latest version.
2. Verify that an LAN/ICSNet cable is connected from the NI Controller to the LAN Hub.
3. Connect an programming cable (RS-232) from the Program Port on the NI Controller to a COM port on
the PC being used for programming.
4. Verify that any control cards (NI-4000 and NI-4100 only) are inserted and their respective connectors are
attached to the rear of the NI Controller before continuing.
5. Verify that the NI Controller is powered On.
Preparing the NI Controller for Serial Communication
To establish serial communication with the Controller via the PROGRAM (DB9) port:
1. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx
Studio 2 > NetLinx Studio 2).
2. Select Settings > Master Communication Settings, from the menu bar, to open the Master
Communication Settings dialog box.
3. Click the Communications Settings button to open the Communications Settings dialog.
4. Click the NetLinx Master radio button (from the Platform Selection section) to indicate you are working
with a NetLinx Master.
5. Click the Serial radio button (from the Transport Connection Option section) to indicate you are
connecting to the Master via a COM port.
6. Click the Edit Settings button (on the Communications Settings dialog) to open the Serial Settings dialog
and set the COM port parameters (used to communicate to the NetLinx Master).
7. Click OK to close all dialogs and return to the main application.
8. Right-click the Online Tree tab entry and select Refresh System: the Controller should appear in the
Device Tree. If not, verify that the Serial cable is connected properly, and that the Baud Rate settings on
the Controller (set via the Program Port DIP Switch) match the settings in NetLinx Studio.
Once Serial communication has been established, use NetLinx Studio to configure the Controller for LAN
Communication, as described below.
Before commencing, verify you are using the latest firmware Kit file (this file contains
both the NI Integrated Controller and on-board Master firmware.
The NI-4100/3100/2100 Kit file begins with 2105_04_X100.
The NI-700/900 Kit file begins with 2105_03_NI-X00 and 2105_09_NI-X00
respectively.