59
Lutron® integration protocol
Why Integrate with a HomeWorks® QS Processor?
• Integrating with a HomeWorks® QS Processor provides integration over Ethernet without the need
for additional equipment or interfaces.
• RS-232 integration can also be accomplished using third party Ethernet to RS-232 adapters.
• Integrating directly with the HomeWorks® QS Processor also provides the greatest bandwidth port
into the HomeWorks® QS system.
• Integration IDs are automatically generated by the HomeWorks® QS software application (e.g., for
devices, outputs, shadegroups, timeclocks). Integration IDs can be removed to reduce processing
and traffic of unwanted messages.
• Phantom Keypads allow for integration functionality to be organized on various virtual keypads that
have unlimited buttons and do not count towards link device count limits.
Integration Capabilities
• Control and monitoring of output devices such as dimmers, the GRAFIK Eye®, shades and contact
closure outputs
• Control and monitoring of physical or phantom keypad buttons and button status LEDs
• Control and monitoring of Lutron® HVAC equipment
• Control and monitoring of individual timeclocks
• Control and monitoring of state variables
• Monitoring of occupancy sensors
• Control and monitoring of areas to activate scenes and monitor occupancy
HomeWorks® QS (continued)
Integration Access Points
HomeWorks® QS Processor
Model: HQP6-2