Installation and Wiring
14
PT10-PLV Single Camera Pan/Tilt System
! AXlink data lines (AXM and AXP) are designed for balance-line operation; wire the data
lines in the same twisted pair.
! Use a shielded cable for best results, both to reduce electronic interference radiated by
adjacent wiring and to eliminate noise from AXlink cabling to adjacent audio cabling.
If you find that the included 100' (30.48 m) AXlink cables are not long enough for your application,
use the wire types suggested below to make custom cables.
AXlink - (local-area, low-power requirement)
22/24 AWG 4-conductor cables can be used for short wiring runs.
! Level 3, 4, or 5 unshielded, twisted pair
! Belden 8102, 2 twisted pair, 1 shield 12 pF/ft, PVC and plenum cable available.
AXlink - (local-area, high-power requirement)
Large systems that power many bus controllers or touch panels should use a heavier gauge wire to
handle DC power.
! Liberty Wire and Cable AMX-2S22218 AXlink Cable, one shielded, twisted pair 22
AWG, 12.5 pF/ft, two 18 AWG, PVC and plenum cable available.
AXlink - (wide-area, local-power supply)
In this type of system, power is rarely distributed over the AXlink bus; local power supplies are
used for each controller or linked system.
! West Penn D2401 1 twisted pair, 1 shield 14 pF/ft, plenum cable available.