Installation and Wiring
13
T10-PLV Single Camera Pan/Tilt System
Putting It All Together
1. Connect the green 2-pin PS2.8 power connector to the rear of the AXB-EM232.
2. Make AXlink connections:
a. Connect the AXlink port on the AXB-EM232 to Connector 1 on the ABS.
b. Connect the AXlink port on the AXB-PT10 to open connector on the ABS.
c. Connect the mini-XLR port on the AXP-PLV to an open connector on the ABS.
3. Connect the CC-AXL 2-pin power connector to the PSN6.5 power supply.
4. Connect the lens control cable from the side of the lens to the 6-pin LENS connector on the
rear of the camera.
5. Connect the DB-9 port on the AXB-PT10 to the 8-pin mini-DIN REMOTE connector on the
rear of the camera (for systems where the camera is located within 25 m of the CMA-D2).
For systems where the camera is located over 25 m, use the 4-pin captive-wire to mini 8-pin
DIN cable to connect the CMA-D3 to the AXB-EM232 (RS-232 port 1 on the rear panel of the
AXB-EM232). The CMA-D3 can be located up to 100 m from the camera.
6. Use a BNC cable to connect the VIDEO OUT port on the rear of the camera to the BNC
connector on the rear of the AXP-PLV.
7. Connect the CMA-D2 to the DC IN/VBS port on the rear of the camera.
8. Verify there are no obstructions in the horizontal or vertical paths of the attached camera on the
AXB-PT10.
For best performance, mount the AXB-EM232 as close to the CMA-D2 as possible.
9. Plug in the PSN6.5, PS2.8, and CMA-D2 power supplies to their respective outlets.
10. Allow the AXP-PLV touch panel software approximately 20 seconds for initialization and self-
calibration before beginning use.
Do not move the joystick or the focus wheel while the AXP-PLV is displaying its initialization
page. Self-calibration is in progress.
11. Select the video input for camera one by pressing the Camera Station 1 pushbutton located on
the right side of the AXP-PLV touch panel.
Suggested Wire Types For Custom Cables
AXlink is a control network that uses four wires to carry data and power to all remote devices in the
system. Two wires carry a balanced-line data signal; the other two provide ground and +12 VDC
power. Large distributed systems that use long AXlink runs with a maximum of 3,000 feet
(914.4 m) should use low-capacitance (12-14 pF/ft) shielded twisted pair cable.
! The length of an AXlink wire run is equal to the total length of wire used; a star run made
of one 300' section and six 50' sections equals one 600' AXlink line.
When applying power to the AXB-PT10, adjust the soft-set pan/tilt-limit stops to a safe position to
prevent camera or AXB-PT10 damage.