Common Setup Ver. 0002 GSU - 17
Frecuency
Gain
Fc
Current Command Filter:
Low Pass Filter
FcCP30
100 Hz
200 Hz
300 Hz
400 Hz
500 Hz
600 Hz
700 Hz
800 Hz
8
7
6
5
4
3
2
1
100 Hz
800 Hz
no filter0
Parameters CP20 -F00307- and CP30 -F00308- can be modified at the OEM access level.
Current command limit CP20 -F00307-
It is a parameter that is factory set to the value that protects the motor and the drive
against overcurrent.
- On servo systems with an FXM motor, CP20 takes the smaller of the values given
by the peak current of the drive and that of the motor.
- On systems with an SPM motor, it takes the value of the maximum current of the
drive. On applications requiring lots of power when threading, the value of CP20 may
be up to 15% higher than the maximum current of the drive.
Current command filter, CP30 -F00308- and CP31 -F00312-
Some FXM motors generate a high-pitch noise that may be eliminated using a low-
passing filter for the current command.
This filter is not applicable to systems using SPM motors.
This filter may be configured by giving its natural frequency and the damping factor.
Break frequency:
Giving to CP30 -F00308- CurrentFilter1TimeConstant a value between 0 and 8, sets
the break frequency of this filter.
Comentarios a estos manuales