Configuring the NXB-CCG
7
RPM Device Configuration Guide - NXB-CCG NetLinx Clear Connect Gateway
6. Change the ID for this keypad to match the Integration ID indicated in the RPM Project report.
FIG. 16 provides an example RPM Report entry for the CCD-W6BRL Keypad, indicating that the keypad’s
Integration ID is "10":
In this case, the ID in the WebConsole must be changed from the default value of 2 to match the Integration ID
value (10):
a. Click in the ID cell of the keypad to open an edit window (FIG. 17):
b. Enter the Integration ID that is indicated for the keypad in the RPM Project report.
c. Press Save to assign the new ID.
Adding a Clear Connect Occupancy Sensor
RPM supports the CCD-OCRB-P (-WH) Ceiling Mount Occupancy Sensor (FIG. 18):
FIG. 15 NXB-CCG WebConsole - "Keypad" added
FIG. 16 RPM Project Report - CCD-W6BRL Keypad
FIG. 17 NXB-CCG WebConsole - Device ID popup (Keypad)
FIG. 18 CCD-OCRB-P (-WH) Ceiling Mount Occupancy Sensor