OFPC Project No. 703-039 M.D. ANDERSON CANCER CENTER
Ambulatory Clinical Building
55050.00
AV BID AUDIO VISUAL SYSTEM
03/11/04 11738 -2
Bind product data sheets together either in GBC or 3-ring type binders.
3. Timetable
Submit total quantity of complete sets of Product Data as required by General Conditions, no later
than 30 days after award of contract. Partial submittals are not acceptable.
Allow minimum of 30 days for review. Two sets will be returned with review comments. If
resubmittal is required, resubmit total quantity of complete sets. If second resubmittal is
required, Contractor shall reimburse Owner for expenses incurred during additional review
process.
Obtain approved Product Data before commencement of work.
C. Shop Drawings
1. Number of Sets: 6.
2. Minimum Scale
a. Floor Plans: 1/8 inch = 1 foot
b. Rack Elevations: 1-½ inch = 1 foot
c. Plate/Panel Details: 6 inches = 1 foot
d. Loudspeaker Details: 1 inch = 1 foot
3. Include as a minimum:
a. Floor plans indicating locations of devices, vertical risers, pull boxes, and exposed wiring.
b. Loudspeaker orientation details.
c. Mounting detail drawings of loudspeakers, racks, and overhead equipment. Hire services of
professional structural engineer, licensed to practice in the State of Texas, to review shop
drawings, building structural drawings, and any existing structures from which equipment is to
be suspended. Include Structural Engineer’s stamped report with shop drawing submittal.
Report to include: (a) itemization of items reviewed by the Structural Engineer, (b)
confirmation that proposed methods of suspending equipment as shown on the shop drawings
conform to required safety factors, and (c) confirmation that building structure from which
equipment is to be suspended will support equipment including required safety factors.
Rack elevations
Complete schematic diagram. One-line diagram with detailed descriptions of product inputs and
outputs is acceptable. Include terminal strip details and cable label information. If wiring
diagram spans more than 3 sheets, additionally provide simplified block diagram of entire
system on 1 sheet.
Electrical power wiring diagram. Include circuit, switching, and control details.
Wiring diagram of grounding and shielding scheme.
Drawings for custom-fabricated items (i.e., plates, panels, cables, and assemblies).
General construction drawings necessary for completion of work.
4. Guidelines
a. Shop Drawings to be used for coordination between trades and updated as final record
drawings.
b. Number and title each drawing in logical manner as a set.
c. Include on each drawings: Project, Building, location, Contractor Name, Architect, Acoustical
Consultant, date, and revision number.
d. Ensure that labeling on Shop Drawings match labeling on equipment.
e. Bind Shop Drawings together to form set. Loose drawings will not be accepted.
f. Copies of electronic CAD files including Contract Drawings will be made available from
Consultant in AutoCAD LT 2000 or LT 2002 format.
5. Timetable
a. Submit total quantity of complete sets of Shop Drawings as required by General Conditions,
no later than 30 days after award of contract. Partial submittals are not acceptable.
b. Allow minimum of 30 days for review. Two sets will be returned with review comments. If
rresubmittal is required, resubmit total quantity of complete sets. If second resubmittal is
required, Contractor shall reimburse Owner for expenses incurred during additional review
process.
c. Obtain approved Shop Drawings before commencement of work.