8
5. Previously, if CC64s were missing from the network at power-up or when the design is sent to
PM8500N hardware, communication with the amplifier could be disrupted for couple of minutes, this has
now been reduced to 20 seconds. #6875 (
6. Operation of the CC-64 in PM8500N only systems has been further improved and the LED ladders
should no longer become out-of-sync if the volume is adjusted quickly. (#6209)
7. An issue with the CC-16/64 lock feature has been resolved and they should now function in mixed ESP
and PM systems; however changing lock status repeatedly via Parameter Set may cause a disconnect
whilst online. (#4949/6912)
8. The ability to dynamically re-assign CC-64 controls has been improved and now works with mixed
ESP/PM systems; however the issue of LED ladders being unlit and the level jumping to -60db as the
encoder is rotated left may still occur on larger systems. (#6106)
9. Previously the first push of the CC-16 ‘Select’ buttons (with the backlight off) was being stored in
addition to turning on the backlight, which meant the assigned selector would change 2 steps with the
second push. This has now been corrected. (#4807/6821)
10. An issue whereby two or more CC16s dynamically assigned to the same selector object could
become out-of-sync when using the ‘Select’ buttons on the CC-16 simulators in ControlSpace Designer
has been fixed. (#4823)
11. Several issues related to the behavior of CC-16s and CC-64s have been resolved and the level of –inf
is now displayed consistently as ‘Off’ to the end-user. Also, it is no longer possible for the CC-16 to
display ‘Mute’ when audio is passing. (#4712/4784/4887)
12. An issue which meant that CC-16/CC-64 simulators could display incorrect labels after the
assignment was changed via Parameter Set has been resolved. (#4954/4955)
13. Uploading a file with a CC lock assigned to GPI will no longer cause an error. (#5035)
14. The default step size for CC-64 has been changed to 1dB.
15. Several issues that affected CC-16/ 64 or serial operation in larger systems as a result of the Group
master and member levels becoming out of sync if the power or network connection for one of the
devices was disrupted have been resolved. (#6607-9/6614-16)
16. An issue whereby the maximum level for a CC-16/64 was not recalled correctly when the assignment
was changed via Parameter Set has been resolved. (#6711)
17. With the previous version it was possible to incorrectly assign PM8500 (USB only) outputs to a CC-16
or CC-64, this has now been corrected.
18. When recalling a parameter set that includes a user interface with a ‘blank’ assignment the smart
simulation windows in ControlSpace Designer are now updated correctly. (#4791)
19. Changes made via the CC-64 simulator to Groups that include members from devices other than the
‘main’ device are now correctly reflected in the hardware and the two no longer become out-of-sync.
(#6354)
20. In earlier versions Parameter Sets were not removed from stored CC assignments when
cleared/deleted resulting in errors when uploading, this no longer occurs. (#5160)
21. An issue whereby changes made to the EQ gain parameter of grouped PM8500/N SpeakerPEQ
modules were not reflected in the other group members is fixed. (# 6395)
Comentarios a estos manuales