2. The PM8500/N Recovery Mode is now correctly supported via USB allowing a new firmware image to
be sent in the event of corruption or update failure. (#6519)
3. When performing a firmware update with multiple devices, should one fail, the process now continues
and successfully updated devices are automatically rebooted. (#6497)
4. An issue that could occasionally cause PM8500/Ns to enter a 'FAULT Amp x (or Power Supply)
Temp Above Max’ state shortly after power up has been resolved. (#6558/6582)
5. PM8500/N limiter settings are now changed automatically when changing outputs between High-Z
(70/100V) and Low-Z operation, even when a loudspeaker preset is loaded. (#6543)
6. Several issues that could result in limiter and protection gain reduction being applied incorrectly have
been resolved. (#6537/6544/6332/6333/6334)
7. Limiter values are now correctly constrained to the maximum permissible value for the mode when
adjusting limiters or loading EQ presets from front panel. (#6623/6522)
8. Copy/paste of a CC16 in Project View no longer causes an error when attempting to send the design to
an ESP-88/00 (#6506)
9. An earlier issue that caused CC-16s or CC-64s not to unlock correctly when controlled Parameter Set
has now been resolved (#4949)
10. An issue whereby volume levels displayed on CC-64s can get out-of-sync if the same PM8500N
output is assigned to multiple controls/CC-64s has been resolved. (# 6312)
11. Update of CC-64 LED ladders and displayed values has been significantly improved for PM8500N
only systems (#6209)
12. Issues that could result in CC-64 labels being lost or not being updated correctly in PM8500N only
systems have been resolved. (#6549/6583)
13. PM8500N signal processing modules that could incorrectly be added to the CC-64 Custom Mode are
now restricted as expected. (#6546)
14. An issue that could result in ESP-88/00 mute states becoming out-of-sync between CC-64 hardware
and simulator if encoders were push simultaneously has been resolved. (#6007)
15. The default step-size for a volume control on a CC-64 has been returned to 0.5dB for this release.
16. Previously it was possible to store conflicting values for the PM8500N Band Pass and Speaker PEQ
modules in a parameter set which could lead to unexpected results. This is no longer possible because
the high/low pass parameters are now only stored with the Band Pass module, not with the Speaker PEQ
module. (#6617)
17. Changes made to the EQ gain parameter of a grouped Speaker PEQ module in the PM8500N are
now reflected in the other group members as expected. (# 6395)
18. The correct loudspeaker preset label for the PM8500N Speaker EQ module is now displayed when
downloading irrespective of whether changes were saved to flash (#5571)
19. Copy/Paste of an unlocked PM8500/N Speaker PEQ module no longer pushes attack/release settings
to limiter unexpectedly. (#6437)