4. With multiple ESPs in the project and groups controlled via a CC-64, the CC-64 display could be slow
to update if the encoder was turned quickly. This has been improved significantly for ESP systems, but
can still occur in PM8500N only systems. (#4937)
5. Under certain conditions it was possible for the CC-64 to appear frozen and operating the encoders
would have no effect. This issue has been addressed, however similar symptoms can also be observed if
the network connection between the CC-64 and the ESP/PM is lost. (#xxxx)
6. If a volume Group was set to the same level by multiple Parameter Set recalls (without the level being
changed in-between) it was possible for the members of the Group to become out-of-sync with the
master. This has now been resolved. (#4871)
7. When opening configuration files that originated in v1.001 with ControlSpace Designer v2.200 (or
v2.075) it was not possible to add additional devices or processing modules. This has now been
corrected. (#4809)
8. Previously, uploading a design that contained a 402-II full-range loudspeaker EQ or selecting the 402-II
full-range option in the loudspeaker EQ module would cause an audible ‘pop’. This has now been
resolved. (#4946)
9. An issue that caused selectors dynamically assigned to CC-64s to revert back to their stored value
when ControlSpace Designer was on-line has been fixed. (#4753)
10. An issue that caused CC-64 LED ladders not to light when the assignment was changed dynamically
(with no change to the volume levels) has been partially fixed. The LED ladders now light correctly when
assignments are changed, but the CC-64 may need to be rebooted after the initial upload. Note that use
of dynamic reassignment with PM8500Ns in the project is not currently supported. (
11. The CC-64 would occasionally enter ‘Custom Mode’ unintentionally when processing modules were
assigned in the ‘Custom Mode’ tab and Parameter Sets were recalled. This no longer occurs. (#4853)
12. An issue whereby a selector module from any ESP other than the ‘RTC’ ESP assigned to a CC-64 in
a multi-ESP project could cause the ‘RTC’ ESP to halt when the selector was changed via ControlSpace
Designer has been resolved. (#4792)
13. An issue that caused selectors assigned to CC-16s to revert back to their stored value when the re-
assignment parameter set was recalled via ControlSpace Designer has been resolved. (#4797)
14. Previously, unlocking a CC-16 or CC-64 via Parameter Set also removed the control assignments.
This has now been resolved for the ESP. Note that locking or unlocking user interfaces in PM8500N only
systems is not supported in this release. (#4949)
15. Once CC-16s are linked to an ESP they move from the top of the Project Directory to their new
location under the appropriate ESP. In previous versions this move did not occur until the file was re-
opened; it now happens immediately. (#4867)
16. An issue whereby the Group increment serial command (SH) did not function correctly if the gain was
set to inf has been resolved. With the gain set to inf the first increment command changes the gain to -
60dB and then subsequent commands increment the gain as expected. (#4830)
17. Actions assigned to the ‘Off’ state (or minimum volume) of a GPI contact are now correctly invoked at
power-up. (#4840)
18. The pop-up faders in the AMM and Surround card modules now correctly sync to the current level
when opened. (#4802/4807)