14. Depending on the number of ESPs in a project it is possible for Group volume adjustment via CC-
16 to become a little ‘jumpy’. (#6525)
15. Mute-only group labels are not displayed correctly on the CC-64 when assigned to the control
dynamically. Level+Mute groups behave as expected and using Parameter Sets is an alternative.
(#7025)
16. Recalling Parameter Sets that include the CC-lock parameter in quick sucession may cause the
ESP to become un-responsive and disconnect. In normal operation it should be fine. (#6912)
17. Currently some PM8500N modules assigned directly to ESP timer events may not invoke
parameter changes or update ControlSpace Designer correctly. It is recommended that changes
are made via Parameter Sets for the time-being. (#6838-9, #6833-4)
18. Using ‘undo’ after moving or making changes to the PM8500/N may be problematic, it is
recommended that you avoid using ‘undo’ with PM where possible. (#6878)
19. If a PM8500N firmware update via Ethernet is interrupted during the initial stages a reboot may
be required to fully re-establish communications. (#6009)
20. The X-Curve function in the Surround Sound Card remains un-operational in this release.
21. It is possible that some paths may not pass audio correctly when there are more than 3-4 AMM
blocks in an ESP system design. (#)
22. When an input channel of the AMM module is set to ‘Use Channel Settings’ from another the
values are not correctly updated if the properties window is open. Either close and re-open the
channel properties window, or re-select the source channel from the list. (#4787)
23. With certain configurations it is possible that the DSP resource requirement is underestimated
which can result in audible distortion if a design is loaded with greater than 97% usage. Try to
keep DSP resource requirement under 95% or add the DSP expansion card. (#4789)
24. Gains set to inf are not saved correctly when using Polish or Russian operating systems which
results in an error when trying to re-open the file. (#4850)
25. Performing load measurements on channels with grouped delays will cause metering to stop
operating, and will generate a network error when going offline.
26. ESP Limiter PeakRMS attack/release settings do not behave like PowerMatch settings. 6926 P1
27. ESP disconnects and CC-16 is freezing when trying to invoke Parameter Sets via CC-16 (hardware
or simulator) on a large system. 7073 P1
28. CC-64 LED ladders disappear when assignment changed and PowerMatch amplifier is present
with ESPs. 6106 P2
29. Incorrect parameter set values will be shown in CSD if parameter sets are recalled 'quickly' when
online with PowerMatch amplifiers. 6426 P2
30. CC64 is blank after upload when a PowerMatch amplifier is present. 6631 P2
31. A CC-64 that’s not on the network can cause PowerMatch amplifiers to not respond for up to 3
minutes. 6875 P2
32. Need to change metering priority to try to prevent CSD from hanging in large systems w/ lots of
traffic. 7021 P2
33. Need to change metering rate to reduce network traffic. 7022 P2
34. PowerMatch amplifiers and ESPs are disconnected from CSD and/or metering fails after high
CC64 traffic in large systems. 7031 P2
35. ESP can become disconnected after multiple CC64 reassignments take place. 7042 P2
36. PM8500N doesn't respond correctly to analog GPI changes from the ESP. 7063 P2
37. PM8500/N & PM8250/N Quad mode meters display "standby" text vertically instead of
horizontally within wide meters on the front panel. 7106 P2
38. May receive multiple timeout errors on upload of a 20 device design file to ESP. 7116 P2
39. System Memory Exceptions may occur with repeated opening of large system files - CSD
memory cleanup limitations. 7131 P2
40. Long timeout time where CC64s can become unresponsive for 30s to 2min. 7133 P2
41. Multiple CC64 control issues can occur after power-cycling system, especially if CC64s powered
on last. 7134 P2