20. Open circuit detection relies on program material for impedance testing, and due to varying program
material may not always work on some channels with only high frequency program content. False
detection of open faults on outputs connected to RoomMatch HF modules has been reduced. (#6178)
21. Performing PM8500N load measurements on channels with grouped delays could cause metering to
cease and an error when going offline, this has now been resolved. (#6491)
22. An issue that caused the USB connection to break following a load measurement on the PM8500/N
has been corrected. (#6601)
23. Management of load measurement data in the design file has been improved a little to reduce file size
issues for larger systems. (#6490)
24. Performing a scan with a PM8500/N in the design no longer causes the PM8500/N input labels to be
lost/reset . (#6511)
25. An earlier issue whereby Groups were not included in a Parameter Set copy/paste has been resolved.
(#6447)
26. An issue whereby levels stored at –inf in a Parameter Set would be incorrectly changed to -8dB when
the file is saved and re-opened has been resolved. (#5041)
27. When the ESP-88/00 Comp/Lim ratio was set to inf:1 (or stored in a parameter set) it was incorrectly
changed to 8:1 when the file was re-opened, this no longer occurs. (#6598)
28. PM8500N Signal Generator routing is no longer included when adding the Matrix Mixer to a
Parameter Set (#5609)
29. It is no longer possible to group incompatible limiter modules on the PM8500N via the Add to Group
option. (#6625)
30. An issue whereby Parameter Set recall could fail, or two identical devices could appear in the
Parameter Set after starting a new file and downloading has been resolved. (#6619)
31. An issue whereby a PM8500N could return to factory defaults if groups were being used and the IP
address of the hardware was changed without also changing the address within the design file has been
resolved. (#6513)
32. Previously changing the PM8500/N output configuration from Mono to Quad to Mono on some
channels could cause the hardware to freeze. This has now been resolved (#
33. Following changes to output configuration it was previously possible for the Signal Generator routing
on the PM8500/N to be shown incorrectly in the Matrix Mixer, this is resolved.(#6346)
34. The Device list is now displayed correctly when restarting ControlSpace Designer in full- ‘Designer’
mode after having used 'Monitor Mode' (#6282)
35. When connecting via USB you are no longer presented with the "Settings have changed" dialog when
going offline if the option to auto-save settings to flash is checked. (#6389)
36. An issue whereby PM8500s (USB only) were incorrectly reported as missing when connecting via
Ethernet has been partially resolved. Now only occurs for quick-reconnect. (#5465)
37. When a PM8500N is connected via USB and the network address of the hardware and ControlSpace
Designer differ, the actual hardware network address is now displayed in the update utilities as expected.
(# 6277)