21
Rosemount 3300 Series
October 2014
www.rosemount.com
Interface Measuring Range
Target applications include interfaces between oil; oil-like and water; and water-like liquids with a
low (<3) upper product dielectric constant and a high (>20) lower product dielectric constant. For
such applications, the max measuring range is only limited by the length of the coaxial, rigid twin
and rigid single lead probes.
For the flexible twin lead probe, the maximum measuring range will be reduced depending on the
maximum upper product thickness according to the diagram.
Example: If the Upper Product Dielectric Constant is 2, and the Upper Product Thickness is 5 ft.
(1.5 m), the Maximum Measuring Range is 75.5 ft. (23 m).
However, characteristics vary between different applications. For other product combinations,
consult your local Emerson Process Management representative.
Environment
Vibration Resistance Polyurethane-covered aluminum housing: IEC 60770-1. SST housing: IACS E10
Electromagnetic
Compatibility
Emission and Immunity: meets EN 61326-1 (2006) and amendment A1, class A equipment
intended for use in industrial locations if installed in metallic vessels or still-pipes.
When rigid/flexible single and twin lead probes are installed in non-metallic or open vessels,
influence of strong electromagnetic fields might affect measurements.
Built-in Lightning Protection Meets EN 61000-4-4 Severity Level 4 and EN 61000-4-5 Severity Level 4
Coating
(See Table 8 on page 23)
Single lead probes are preferred when there is a risk for contamination (because coating can
result in product bridging across the two leads for twin versions; between the inner lead and
outer pipe for the coaxial probe).
PTFE probes are recommended for viscous or sticky applications. Periodic cleaning might be
required.
For viscous or sticky applications, it is not recommended to use centering discs mounted along
the probe.
Maximum error due to coating is 1 to 10% depending on probe type, dielectric constant, coating
thickness, and coating height above product surface.
CE-mark
The 4–20 mA HART version (Output Option Code H) complies with applicable directives (EMC and
ATE X).
0 (0) 3.3 (1)
65.6 (20)
68.9 (21)
72.2 (22)
75.5 (23)
78.7 (24)
82.0 (25)
2
3
5
6.6 (2) 9.8 (3) 13.1 (4) 16.4 (5)
Maximum Measuring Range, Flexible Twin Lead Probe, ft. (m)
Upper Product
Dielectric Constant
Max Upper Product Thickness, ft. (m)