KI-1856C Rauland RANGER
®
Head End—
Installation
Page 13 of 55 (Jun-98)
RANCPU Control System Master Card
The
RANCPU
decodes all messages from classroom control panels (
RANCLASS1
or
RANCL201CP
) or remote control units (
RANHHELD
). Unless a
RANEXP
or is used, each
system must include one
RANCPU or RANBROAD
. This control-system master card
mounts in the
RANCC16
Control Card Cage and can handle control-link cable runs with
up to 60,000 pF of capacitance. See Table 3 to determine the requirements for your
system. If the capacitance per foot of the cable that you are using exceeds the maximum
cumulative distance indicated in the chart, you will have to use a
RANEXP
or
RANBROAD
in place of, or in addition to, the
RANCPU
(see “
RANEXP
” or
“
RANBROAD
” for more information).
The
RANCPU
is typically connected directly to the
RANPCSW
computer for programming purposes via the
VW
2302 cable (supplied with the
RANPCSW
).
Table 3. Maximum Cable Distances for Use with the
RANCPU
Cable Capacitance per Foot
Maximum Cumulative
Distance (in Feet)
WP D291 26 2,300
WP 291 45 1,200
WP D2401 14.5 4,000
WP D252401 (Plenum) 14.5 4,000
Belden 8102 12.5 4,500
Parts Required