NI-2000 Specifications (Cont.)
Rear Panel Connectors (Cont.):
Relay (Port 4) Four-channel single-pole single-throw relay ports
Each relay is independently controlled.
Supports up to 4 independent external relay devices
Channel range = 1-4
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
8-pin 3.5 mm mini-Phoenix (female) connector provides relay termination
Digital I/O (Port 9) Four-channel binary I/O port for contact closure
Each input is capable of voltage sensing. Input format is software
selectable.
Interactive power sensing for IR ports
Channel range = 1-4
All inputs are assigned to respective IR/Serial ports for "automatic" power
control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).
Contact closure between GND and an I/O port is detected as a PUSH
When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as
a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE
When used as an output - each I/O port acts as a switch to GND and is
rated at 200 mA @ 12 VDC
6-pin 3.5 mm mini-Phoenix (female) connector provides I/O port
termination
Note: This IO port uses 5V logic but can handle up to 12V without harm. It
can handle up to 12V on the input. At higher voltages you run a higher risk of
surge damage.
IR/Serial (Ports 5-8) Four IR/Serial control ports support high-frequency carriers of up to
1.142 MHz.
Each output is capable of three electrical formats: IR, Serial, and Data
Four IR/Serial data signals can be generated simultaneously.
Channel range = 1-32,767
Channels 1-128 (output): IR commands
Channels 129-253: used as reference channels
Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
Channel 255 (feedback): Power status (when IO Link is set)
IR ports support data mode (at limited baud rates and wiring distances).
8-pin 3.5 mm mini-Phoenix (female) connector provides IR/Serial port
termination
Program port RS-232 DB9 connector (male) can be connected to a DB9 port on a
computer; used with serial commands, NetLinx programming commands,
other DB9 capable devices, and to upload/download information from the
NetLinx Studio 2.4 program.
Configuration DIP switch Sets the communication parameters for the Program port.
ID pushbutton Provides the NetLinx ID (Device only) assignment for the device.
The D notation is used to represent a device number.
Refer to the NetLinx Integrated Controller WebConsole & Programming
Guide for details.
Ethernet port RJ-45 port for 10/100 Mbps communication. This port automatically
negotiates the connection speed (10 Mbps or 100 Mbps) and whether to
use half duplex or full duplex mode.