Wiring and Connections
25
Metreau Keypads
Two-Wire Configurations – Keypad for Control Only
In some retrofit configurations it is not feasible or possible to re-route the speaker cable through the keypad. In
cases such as this, it is possible to run a separate cable pair (CAT-3 / CAT-5 / Twisted Pair) cable from the
Matrix Controller to the keypad for control purposes.
When using CAT3/CAT5 over long runs, it is recommended to "double-up" the control wires (only 2
conductors are required, and there are 4-8 wires available).
FIG. 28 shows the connections of the control signal path to the keypad, and the speaker connections to the
Matrix Controller.
FIG. 11 2 Wire Configurations - keypad for Control Only
Metreau keypad
+-+-
Left Right
Cat5/Cat3/Twisted Pair
LD G R
Zone Output Connector
(on Matrix Controller)