AMX NI-3100 Especificaciones Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 160
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
Initial Configuration and Firmware Upgrade
8
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
Obtaining the NI Controller’s IP Address (using DHCP)
1. In NetLinx Studio, select Diagnostics > Network Addresses from the Main menu to access the Network
Addresses dialog (FIG. 7).
2. Verify that both the System number corresponds to the System value previously assigned within the
Device Addressing tab and that zero (0) is entered into the Device field.
3. Click the Get IP Information button to configure the on-board Master for DHCP usage and then read the
IP Address obtained from the DHCP Server.
4. Note the obtained IP Address (read-only). This information is later entered into the Master
Communication Settings dialog and used by NetLinx Studio v 2.x to communicate to the NI Controller
via an IP. This address is reserved by the DHCP server and then given to the Master.
5. Verify that NetLinx appears in the Host Name field (if not, then enter it in at this time).
6. Click the Use DHCP radio button from the IP Address section.
7. Click the Set IP Information button to retain the IP Address from the DHCP server and assign it to the
on-board Master. A popup window then appears to notify you that Setting the IP information was
successful and it is recommended that the Master be rebooted.
8. Click OK to accept the change to the new IP/DNS information.
9. Click the Reboot Master button and select Yes to close the Network Addresses dialog.
Verify there is an active LAN connection on the NI Controller’s LAN port before
beginning these procedures.
FIG. 7 NetLinx Studio: Network Addresses dialog (for a DHCP IP Address)
System Address
reflects the value
set in the Device
Addressing tab
Used to obtain a
Dynamic (DHCP)
IP Address
The system value must correspond to the Device Address entered in the Device
Addressing dialog. Refer to the Manage System - System Number section on
page 39 for more detailed instructions on setting a system value.
DO NOT enter ANY IP information at this time; this step only gets the System Master
to recognize that it should begin using an obtained DHCP Address.
If the IP Address field is empty, give the Master a few minutes to negotiate a DHCP
Address with the DHCP Server, and try again. The DHCP Server can take anywhere
from a few seconds to a few minutes to provide the Master with an IP Address.