A lightweight communication protocol analyzer has a Data Logger function to record
data in the SD card for long hours.
This device can be used as a PC-connectable Protocol Analyzer for use in the lab (Remote mode), and also as a PC-less Data Logger for use at
on-site tests to record data for long hours (Logger mode).
Measured data is saved as log files of the specified file size in the HDD of
the PC (Remote mode) or in the SD card of the analyzer (Logger mode).
It automatically records data until reaching the specified number of files,
and then deletes the oldest
file to record the new file. Also,
it can stop measurement on
reaching the specified number
of files. It is useful for
detecting any hindrance in
the line.
Long Hour Recording
Schedule Measurement by Inner RTC
Communication log files can be viewed
in detail on a PC. It offers seamless
operation that handles a single
measurement log file even when all
files are read collectively. The
measured data can be converted into
text or CSV format to use in a word
processor and/or spreadsheet software.
Seamless access to communication log files
Monitor data at any speed by setting the baud rate of any four digits.
The high-precision timer makes it possible to record idle time and time
stamps along with data, and is not related to the performance of the PC.
Measures at Arbitrary Speed.
It incorporates an easy-to-use simulation function that makes it possible
to transmit preset transmission data (16 types of data), or fixed data such
as FOX messages, at the flip of a key while checking reception data.
Easy-to-Operate Simulation Function
A newly developed instant power failure prevention circuit protects important
communication log files stored in the SD cards, by protecting the SD cards
from being corrupted even if power fails while recording data to the SD card.
Protects important data from corruption due to power failure
Small and robust housing suitable for severe field environments
[ Record Control Setting ]
*1: For attaching the optional DIN rail plate. Pitch: 70mm. Depth: 3.5mm (max).
RUN / STOP
Switch
SD Card
Slot
USB
Connector
DC Jack
Two-color
LED
Compact Size, Simple Operation
Two Types of Operations Based on Usage Situation.
Compact Size, Simple Operation
Two Types of Operations Based on Usage Situation.
The device comes standard with RS-232C/RS-422/RS-485 interfaces,
which are used widely in medical equipment and electronic products.
With an optional TTL probe pod (OP-5M), it can monitor TTL-level
communication at 2.5V/ 3.3V/ 5V. LE-200PS can measure Sync
communication, which has transmission/ reception clocks.
Supports RS-232C/RS-422/RS-485 (Standard Feature)
*1: A terminal-supplied power from analyzer. ON/OFF
switchable.
*2: LE-5TB is useful for connecting the signals.
*3: LE-200PS only.
*4: Signal pins not defined here are not connected.
Signal
FG
RS-232C SD
RS-232C RD
RS-232C RS
RS-232C CS
RS-232C DR
GND
*2
RS-232C CD
+5VDC
*1
RS-422 RXDB+
*2
RS-422 RXDA-
*2
RS-422 RXCB+
*3
RS-422 RXCA-
*3
RS-232C ST2
*3
RS-232C RT
*3
RS-422/485 TXDB+/TR+
*2
RS-422/485 TXDA-/TR-
*2
RS-232C ER
RS-232C CI
RS-232C ST1
*3
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
15
17
18
19
20
22
24
Pin Assignment of Connector (DSUB 25 pin)
[ Terminal Block Adapter (LE-5TB) ]
[ TTL Monitor Probe Pod (OP-5M) ]
[ Example of Simulation ]
[ Simulation Data Tables ]
[ Text Conversion Setting ]
RS-232C / RS-422 / RS-485
Communication Protocol Analyzer
[ Recording Time ]
*: In the case of full-duplex transmission of 1K byte data at 1ms intervals.
Capacity: 1.8G byte (e.g. 4M byte×450 files)
Approx. 100 Hours
Approx. 4 Hours
Baud Rate
9600bps
230.4Kbps
Communication errors can be detected with high reliability.
It can judge parity error, framing error, BCC error of various block check
codes, and short SDLC/HDLC frame (LE-200PS only). It can find the
communication sequence in the event of an error, by setting an
application-level error notification character string to the character string
agreement criteria of the triggering function. It can notify an error to
external devices and alert a communication error in the logger mode
(with a panel LED lighting), by specifying an external trigger signal
output and user-defined LED lighting as a triggering action.
It is useful in the situations of:
*PC usage is not allowed.
*Dusty places (PC cannot be used).
*Need to record data for more than one month.
*Cannot operate the analyzer well
Logger Mode
(PC less)
*
There are space limitations.
Record in the SD card
Remote Mode
(PC connected)
Real Time Clock (RTC) backed up by
the battery of the analyzer makes it
possible to specify the starting and
ending times of the measurement. After
the measurement, it turns off the power
automatically and saves on power
consumption.
PC
Developing Device
Analysis PC
Connect to PC
via USB
Record in the HDD of PC
[ Dust-proof Covers ]
[ Data display example ]
[ Data display example (Control line information is displayed.) ]
[ Onto 35mm DIN Rail ]
[ Auto RUN/STOP setting ]
[ Configuration Setting ]
[ Trigger Setting ]
PLC Robot
M3 Screw Holes
*1
Measurement Connector
External Signal
Terminal
The palm-sized robust unit can be used between –10 to
+55̊C. It operates not only on USB bus power, but also on
external DC power of 8 to 26.4V. The consumption current
is as low as 100mA at DC12V input. The SD card slot and
the USB connector are equipped with a dust-proof cover
that allows 2-way operation. It can be fixed easily to the
equipment to be examined or built into an inspection line,
since it is compatible with 35mm DIN rails.