NXC-VAI4 Analog Voltage Control Card
29
NetLinx Cardframe, Control Cards, and NetModules
Channel Assignments
The channel ON/OFF assignments for the NXC-VAI4 are described in the following table.
Off = 50% voltage, and all channel assignments are mutually exclusive.
NXC-VAI4 Channel Assignments
Channel State Function
1
ON While channel 1 is ON, the voltage on Output 1 will ramp up at the "CURRENT
OUTPUT 1 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF Stops voltage ramping on Output 1 at current value.
2
ON While channel 2 is ON, the voltage on Output 2 will ramp up at the "CURRENT
OUTPUT 2 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF Stops voltage ramping on Output 2 at current value.
3
ON While channel 3 is ON, the voltage on Output 3 will ramp up at the "CURRENT
OUTPUT 3 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF Stops voltage ramping on Output 3 at current value.
4
ON While channel 4 is ON, the voltage on Output 4 will ramp up at the "CURRENT
OUTPUT 4 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF Stops voltage ramping on Output 4 at current value.
5
ON While channel 5 is ON, the voltage on Output 1 will ramp down at the "CURRENT
OUTPUT 1 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF Stops voltage ramping on Output 1 at current value.
6
ON While channel 6 is ON, the voltage on Output 2 will ramp down at the "CURRENT
OUTPUT 2 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF Stops voltage ramping on Output 2 at current value.
7
ON While channel 7 is ON, the voltage on Output 3 will ramp down at the "CURRENT
OUTPUT 3 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF Stops voltage ramping on Output 3 at current value.
8
ON While channel 8 is ON, the voltage on Output 4 will ramp down at the "CURRENT
OUTPUT 4 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF Stops voltage ramping on Output 4 at current value.
9
ON Reserved [do not use]
OFF Reserved [do not use]
10
ON While channel 10 is ON, the voltage on Output 1 is set to 100%
OFF Sets Output 1 voltage to 50%.
11
ON While channel 11 is ON, the voltage on Output 2 is set to 100%
OFF Sets Output 2 voltage to 50%.
12
ON While channel 12 is ON, the voltage on Output 3 is set to 100%
OFF Sets Output 3 voltage to 50%.
13
ON While channel 13 is ON, the voltage on Output 4 is set to 100%
OFF Sets Output 4 voltage to 50%.
14
ON While channel 14 is ON, the voltage on Output 1 is set to 0%
OFF Sets Output 1 voltage to 50%.
15
ON While channel 15 is ON, the voltage on Output 2 is set to 0%
OFF Sets Output 2 voltage to 50%.
16
ON While channel 16 is ON, the voltage on Output 3 is set to 0%
OFF Sets Output 3 voltage to 50%.