Installation
5
Color Passive-Matrix LCD Touch Panels
2. Carefully insert a flat-blade screwdriver into the release slot on the touch panel’s bezel and
remove the engraved overlay.
3. Lay the touch panel facedown onto a soft cloth and remove the four screws from the low-
profile Back Box. Remove the Back Box and discard.
4. Place the BB-TP2 into the cutout and mark the threaded insert positions as shown in FIG. 3.
5. Remove the BB-TP2 and drill holes (A and B) for the panel (FIG. 3). Then, place #6-32
threaded inserts into the four holes marked 'B' in the cutout dimensions illustration.
6. Disconnect the AXlink connector from the Central Controller. Then, disconnect the optional
RS-232 wiring from the external RS-232 device connected to the touch panel.
7. Remove one or more knockouts to accommodate the wiring as required.
8. Thread the incoming AXlink and RS-232 wiring through the knockouts. Refer to theWiring the
Touch Panel section on page 8 for additional wiring information.
9. Fasten the BB-TP2 to the solid surface using the supplied mounting screws.
10. Connect the AXlink and RS-232 wiring to the touch panel.
FIG. 3 Decor style (AXD) and BB-TP2 cutout dimensions
The touch panel must always be installed with the release slot located at the bottom.