Wiring and Connections
SWT Wiring
DAS-MET-6SRC and DAS-MET-7 Rear Panel Components
FIG. 22 shows the basic rear components of the SWT (DAS-MET-6SRC and DAS-MET-NUM) keypads:
Cable Type
SWT wiring involves connecting the Mi-Series Controller, Metreau keypads, and speakers.
The Mi-Series Controller and Metreau keypads are cabled using standard four-conductor speaker cable
originating at the Controller, passing through the keypad, and terminating at the speaker location.
AMX recommends using a bundled four-conductor 16-gauge stranded copper wire in a single continuous run.
Preparing Captive Wires
SWT wiring utilizes four-color "snap connectors" to secure the wires (no screws). You will need a wire
stripper to prepare and connect the captive wires.
1. Strip 0.25 inch (6.35 mm) of wire insulation off all wires.
2. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and
connector types described in this section.
DAS-MET-6SRC - SWT Data and Power Connections
1.
Connect the Matrix Controller’s Zone Output connector to the four-pin connector on the rear panel of the
Metreau keypad labeled TO CONTROLLER for data and 12 VDC power.
2. Connect the other four-pin connector on the keypad labeled TO SPEAKERS to the SWT speakers as
shown in FIG. 19.
Before touching the device, discharge the static electricity from your body by touching
a grounded metal object.
FIG. 22 DAS-MET-6SRC and DAS-MET-NUM - Rear Components
SWT connector
(from Matrix Controller)
SWT connector
(To speakers)
not used
14-pin connector
(To DAS-MET-NUM)
DAS-MET-6SRC DAS-MET-NUM
14-pin connector
(From DAS-MET-NUM)
Comentarios a estos manuales