3
Approximately 1.3 lb (.61 kg)
Natural convection via air vent openings on front, back
and top
•Enova DGX 8/16/32/64 Digital Media Switchers
•Enova DVX-3155HD, DVX-3156HD and DVX-2155HD
All-In-One Presentation Switchers
•DXLink HDMI RX as a point-to-point solution (when
Wallplates are powered by PS-POE-AT-TC or PDXL-2)
•PS-POE-AT-TC High Power PoE Injector
•PDXL-2 Power over DXLink Controller
CE EN 55022
CE EN 55024
CE EN 60950-1
IEC 60950-1
UL 60950-1
RoHS / WEEE compliant
CC-USB, USB Programming Cable (FG10-5965)
Transport Layer Throughput (Max)
Shielded Cat6, Cat6A and Cat7
DXLink twisted pair cable runs for DXLink equipment
shall only be run within a common building where a
common building is defined as: the walls of the
structure(s) are physically connected and the
structure(s) share a single ground reference
For more details and helpful cabling information,
reference the white paper titled Cabling for Success
with DXLink, or contact your AMX representative
Twisted Pair Cable Length
ACTIVE POWER REQUIREMENTS
Power must be supplied by a DXLink Power sourcing
device such as:
•Enova DGX 8/16/32/64 Digital Media Switcher (with a
DXLink Twisted Pair Input Board installed)
•Compatible Enova DVX All-In-One Presentation
Switcher (DVX-3155HD, DVX-3156HD or DVX-2155HD)
•PS-POE-AT-TC High Power PoE Injector
•PDXL-2 Power over DXLink Controller
When installed in conjunction with an Enova DGX use
the Enova DGX Configuration Tool located at
AMX.com/enova to determine the power
requirements of the configuration
AMX only supports the use of these approved Power
over DXLink solutions. Other third party
power supplies or non-compatible standard PoE
solutions may damage the DXLink equipment. To use
PS-POE-AT-TC or PDXL-2 as a power source the
wallplates require firmware v1.2.40 or above
Included on DXLink Connection
Power over DXLink supplied: 7 W
Comentarios a estos manuales