Pagina 1 - AXB-DMX512

Operation/Reference GuideAxcess ControllersAXB-DMX512DMX512 InterfaceLast Revised: 09/25/2012

Pagina 2

Configuration and Installation6AXB-DMX512 DMX512 Interface5. Place the front panel of the AXB-DMX512 on the front of the rack over the unit and secure

Pagina 3 - Table of Contents

Configuration and Installation7AXB-DMX512 DMX512 InterfaceThere is a danger of explosion if you replace the battery incorrectly. Replace the battery w

Pagina 4 - Document Name Here

Configuration and Installation8AXB-DMX512 DMX512 Interface

Pagina 5 - Product Information

Programming9AXB-DMX512 DMX512 InterfaceProgrammingThe AXB-DMX512 is controlled with Axcess Send_Commands. Use the programming information in this sect

Pagina 6

Programming10AXB-DMX512 DMX512 InterfaceDirect Control Buffer Send_CommandsThe direct control buffer is modified by individual output ramps or by pres

Pagina 7 - Terminating the Device

Programming11AXB-DMX512 DMX512 InterfacePatch Buffer Send_CommandsThe patch buffer Send_Commands determine which if any DMX inputs modify the patch bu

Pagina 8 - Wiring Guidelines at 160 mA

Programming12AXB-DMX512 DMX512 InterfacePatch Buffer Send_Commands (Cont.)Command DescriptionPCPatches an input to one or more outputs.The list can be

Pagina 9 - Using AxLink communication

Programming13AXB-DMX512 DMX512 InterfaceGroup Buffer CommandsThe group buffer is modified by changing group commands. The following table lists the Gr

Pagina 10 - Replacing the Lithium Battery

Programming14AXB-DMX512 DMX512 InterfaceGroup Buffer Commands (Cont.)Command DescriptionGCConnects one or more groups to an Axcess level or to a DMX i

Pagina 11 - AXB-DMX512 DMX512 Interface

Programming15AXB-DMX512 DMX512 InterfaceGroup Buffer Commands (Cont.)Command DescriptionGDRamps down one or more groups at the current ramp rate set b

Pagina 12

AMX Limited Warranty and DisclaimerAll products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from

Pagina 13 - Programming

Programming16AXB-DMX512 DMX512 InterfaceGroup Buffer Commands (Cont.)Command DescriptionGLDeletes DMX outputs from any group.This command removes one

Pagina 14

Programming17AXB-DMX512 DMX512 InterfaceGroup Buffer Commands (Cont.)Command DescriptionGPSame as ‘GA’ command, except the DMX outputs are added so th

Pagina 15 - Patch Buffer Send_Commands

Programming18AXB-DMX512 DMX512 InterfaceGroup Buffer Commands (Cont.)Command DescriptionGRRamps group to a L level in T tenths of seconds. Ramps a sin

Pagina 16

Programming19AXB-DMX512 DMX512 InterfaceGroup Buffer Commands (Cont.)Command DescriptionGT Sets the current ramp rate for one or more groups in tenths

Pagina 17 - Group Buffer Commands

Programming20AXB-DMX512 DMX512 InterfaceAxcess Level Send_CommandsThere are eight levels tied to the Axcess system. The following table lists the Axce

Pagina 18 - Group Buffer Commands (Cont.)

Programming21AXB-DMX512 DMX512 InterfaceAxcess Level Send_Commands (Cont.)Command DescriptionADRamps down one Axcess level at the ramp rate set by the

Pagina 19

Programming22AXB-DMX512 DMX512 InterfaceAxcess Level Send_Commands (Cont.)Command DescriptionATSets the ramp rate for one Axcess level in tenths of a

Pagina 20

Programming23AXB-DMX512 DMX512 InterfaceMiscellaneous Send_CommandsThe following table lists other miscellaneous Send_Commands. M

Pagina 21

Programming24AXB-DMX512 DMX512 InterfaceMiscellaneous Send_Commands (Cont.)Command DescriptionMLDefines the number of output that are transmitted. Lim

Pagina 22

Programming25AXB-DMX512 DMX512 InterfaceChannel CommandsThe following table lists the channel commands for the AXB-DMX512: Ramp time is set by the ‘

Pagina 23

Table of ContentsiDocument Name HereTable of ContentsProduct Information ...

Pagina 24 - Axcess Level Send_Commands

Programming26AXB-DMX512 DMX512 InterfaceChannel Trigger Send_CommandsAlmost all methods of control using an Axcess system require the use of channels

Pagina 25

Troubleshooting27AXB-DMX512 DMX512 InterfaceTroubleshootingThi section addresses and provides solutions to most frequently asked questions. AXB-DM

Pagina 26

Troubleshooting28AXB-DMX512 DMX512 Interface

Pagina 27 - Miscellaneous Send_Commands

Troubleshooting29AXB-DMX512 DMX512 Interface

Pagina 28

9/12 ©2009 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without n

Pagina 29 - Channel Commands

ii Document Name HereTable of ContentsGZ ...

Pagina 30 - Channel Trigger Send_Commands

Product Information1AXB-DMX512 DMX512 InterfaceProduct InformationThe AXB-DMX512 DMX512 Interface creates a bi-directional DMX512 AxLink connection, t

Pagina 31 - Troubleshooting

Product Information2AXB-DMX512 DMX512 Interface

Pagina 32

Configuration and Installation3AXB-DMX512 DMX512 InterfaceConfiguration and InstallationSetting the Device DIP SwitchThe 8-position DEVICE DIP switch

Pagina 33

Configuration and Installation4AXB-DMX512 DMX512 Interface1. Remove the jumper that is on pins 1 and 2 of jumper trios JP4 and JP5. (Pins 1 and 2 are

Pagina 34

Configuration and Installation5AXB-DMX512 DMX512 InterfaceUsing AxLink communicationConnect the AxLink wiring to the connector on the AXB-DMX512, as s

Comentarios a estos manuales

Sin comentarios