16 Installation of GRAFIK5000 / GRAFIK6000 / GRAFIK7000 System
Each device along the Control Station Device
(CSD) Link must have a unique address
ranging from 1 to 32. The Address Switches
may have been pre-set to give the address
shown on the job drawings.
Set Control Station Device Address Switches
Address Switch Settings Chart - shows how to
set the Address Switches to get a specific
address.
Notice!
Do not install a CSD without confirming
that the Address Switches have been
set.
If the Address Switches were not pre-set (all
set to address 1), assign each CSD a unique
address and document its location and
description.
If needed, refer to the instructions for each
CSD to help locate its Address Switches.
2B3
Job drawings may show:
Address 3 ...
on CSD Link B ...
in Processor 2
(omitted if only one processor)
Note
GRAFIK Eye
® Control Units (GRX-46xx-x-xx) do
not have Address Switches but must be
programmed with a unique address(es). See
separate instructions sent with each Control
Unit.