Amx Signature Series NetLinx Integrated Controller NI- Manual de usuario Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
Connections and Wiring
15
NI-3101-SIG Signature Series NetLinx Integrated Controller
3. Remove the rear panel from the device, and then disconnect the NXI control cable and remove the Master
card.
4. Locate the battery behind the Configuration Port on the circuit board.
5. Carefully slide the battery out of its socket and insert the new battery.
6. Plug the 2-pin 3.5 mm mini-Phoenix PWR (green) connector to reapply power. Wait approximately 1
minute, then remove the PWR connector again.
7. Carefully slide the other battery out of its socket and insert the new battery
8. Re-connect the NXI control cable to the Master card.
9. Replace and secure the rear faceplate using the mounting screws and reconnect all communication
connectors.
10. Reconnect the 12 VDC power supply to the respective PWR connector and apply power.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 155 156

Comentarios a estos manuales

Sin comentarios