NXP-CPI16 NetLinx Custom Panel Interface
Each of the two 20-pin connectors is assigned a group of 8 input and output channels. The table below
shows the relation of input and output channels in the STATUS modes.
The NXP-CPI16 may be configured to default to STATUS-ON mode using the following method. The
commands can force a change to the mode no matter what default mode is configured for the device.
STATUS-ON Mode:
Remove R7 (1K ohm) resistor OR short across R8 for STATUS-ON mode. Firmware remains the same
for standard and STATUS-ON mode NXP-CPI16 units.
Input/Output STATUS Mode
Mode Connector STATUS-OFF (default) STATUS-ON
Inputs J3 Chan 1-8 Chan 1-8
J4 Chan 9-16 Chan 17-24
Outputs J3 Chan 1-8 Chan 9-16
J4 Chan 9-16 Chan 25-32