NXB-CCG-K NetLinx ClearConnect Gateway
2
NXB-CCG-K NetLinx® Clear Connect™ Gateway
Product Specifications
NXB-CCG-K (FG2606-868) Specifications
Power Requirements: • Power Consumption: 600mA @ 5VDC, DC adapter optional (5V DC,
3A).
• Surge Protection: To withstand surge voltages without damage or loss
of operation, in accordance with IEEE C62.41-1991 Recommended
Practice on Surge Voltages in Low-Voltage AC Power Circuits.
• Power Failure Memory: If power is interrupted, the NXB-CCG-K will
return to its previous state when power is restored.
Front Panel Components:
Power/Status LED: Displays power status and other system status indicators.
RF LED: Displays the Tx / Rx activity on the RF link.
Ethernet LED: Displays the connection status and Tx / Rx activity on the Ethernet link.
Rear Panel Components:
CAT5 Cable Port: Maximum cable length: 328 ft (100 m).
USB Cable Port: Manufacturer use only.
Reset Button: Press and hold for 30 seconds to restore the system to the Factory Default
settings.
Power Jack (to DC adapter) (IEC PELV / NECR Class 2). This product should be connected to a safety
isolating supply conforming with EN61558.
Operating Environment: • 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing.
• Indoor use only.
ESD Protection: ESD protection to withstand electrostatic discharge without damage or
memory loss, in accordance with IEC 61000-4-2.
Communications: • The NXB-CCG-K communicates to other Clear Connect devices through
RF.
• All devices (except wired accessory dimmers/switches) must be located
within 30 feet (9 m) of the NXB-CCG-K.
Auto Discovery: Supports the ZeroConf auto discovery protocol.
Dimensions (HWD):
• Without antenna: 1 1/8” x 2 5/8” x 4 7/16” (2.86 cm x 6.60 cm x 11.23 cm)
• With antenna: 6 1/2” x 2 5/8” x 4 7/16” (17.15 cm x 6.60 mm x 112.27
mm)
Weight:
0.3 lbs (136.08 g)
Certifications: • CE
Included Accessories: • NXB-CCG-K Installation Guide (93-2606-68)
Other AMX Equipment: • CCD3-OCRB-P-WH, 868 MHz Ceiling Mount Occupancy/Vacancy
Sensor (FG2606-44-WH)
• PS-CCG 5 VDC, 3A Power Supply With 2.1mm Barrel Connector
(FG423-61)
Proper orientation of the antenna helps ensure maximum range and the best
performance. The NXB-CCG-K should be positioned centrally to the devices being
controlled, and as high and clear of obstructions as possible. The NXB-CCG-K
utilizes an omni-directional antenna, which produces a circular pattern perpendicular
to the antenna. For best performance, the antenna should be positioned vertically (tip
up or down, not sideways). Try to keep the antenna at least 2 feet from metallic
objects.