Video Input group: Every video input group has own video input number and P/T/Z Dome ID.
>Group:
Main
/ Card 1 / Card 2 / Card 3 / Card 4 / Card 5 / Card 6 / Card 7 / Extra.
If user does not expand any PCI cards, only have to setup Main group.
Video Channel :Video Channel Number
Camera ID :Input P / T / Z Dome ID
(Video Input Number is fixed, user need to set correct relationship with P/T/Z Dome ID.
Extra :Other Device. Ex : Multiplexer, DVR
For Example:
Set Video Channel Number 1 corresponding P / T / Z Dome ID 33:
A. P / T / Z ID 33 control cable should connect to Matrix RS485 port-10.
(Check the Matrix Device ID contrast table)
B. P / T / Z ID 33 video cable should connect to video channel 1.
C. If user call P / T / Z Dome ID 33 to control and view image, then the image would display
on the Master monitor.
D. Video Channel 257 - 272 is the Extra Device video channel input.
Setup Steps:
1. Choose Video Channels.
2. Use keyboard to key in numbers and must press, “ENTER” to save data.
3. Press “TAB” or click mouse to choose next video channel.
Device Virtual ID Reality ID RS485 Port
P / T / Z Dome 1-32 1-32 Port 9
P / T / Z Dome 33-64 1-32 Port 10
P / T / Z Dome 65-96 1-32 Port 11
P / T / Z Dome 97-128 1-32 Port 12
P / T / Z Dome 129-160 1-32 Port 13
P / T / Z Dome 161-192 1-32 Port 14
P / T / Z Dome 193-256 1-64 Port 15
DVR 1-16 208-223 Port 16
Multiplexer 1-16 224-239 Port 16
Matrix Device ID contrast table